TM 5-3895-374-24-1 Chapter 9 Troubleshooting TROUBLESHOOTING CONSIDERATIONS GENERAL ERROR SCREEN ATTEMPTED FUNCTION PROBABLE CAUSES RECOMMENDED ACTION Use a Quick Recall Function Quick Recall Function Not Defined Assign an address to that function Quick Recall Function Attach to proper node address Defined But That Address is Not Defined In This Processor Enter Setup Procedure Module Not In Modify Mode Change module to Modify mode Enter Password Incorrect Password Entered Enter correct password Data Address Entry Incorrect Format For Address Reenter address correctly Address Not Defined In This Processor Allocate address in memory Data Entry Module In The Monitor Mode Change module to Modify mode Value Out Of Range For File Type Enter value within range Address Is Read Only (Input Or Output File) Abort entry No Response to a Function Key Address Entry In Progress Complete address entry or press the [Esc] key Data Entry In Progress Complete data entry or press the [ESC] key Illegal Command Responding to a Message The Data File That The DTAM Is Trying To Write To Does Not Exist Use the Memory Map function to create the data entry destination or acknowledge bit locations See chapter11 in the Advanced Programming Software User Manual (Catalog Number 1747-NM002). Attach to a 5/03 Processor The Firmware in the DTAM Is Less Than Revision 3 0 and Does Not Support 5/03 Communications Verify the firmware revision number on the DTAM nameplate and contact your local Allen-Bradley sales office for an upgrade Incompat Program Attach to a Processor The User Program in the5103 Processor Is Not Supported by DTAM Abort Contact your local Allen-Bradley sales office Illegal Network LED Flashing Red No Other Nodes Are Active On The Network Attach the required processor to the network. One Or More Nodes On The Network Have An Incorrect Baud Rate Correct the baud rates Network Is Shorted Or Check network cable connections Improperly Wired Module Has Same Node Address As a 5/01 or Fixed Controller (Point- to-Point Connection) Reconfigure the module node address, refer to chapter 3, Module Setup Procedure page 3-399







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.