• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
voltage/frequency
List of the parameters - TM-5-3895-374-24-1_227

TM-5-3895-374-24-1 Paving Machine Bituminous Material: Crawler Mounted Diesel Engine Driven Manual
Page Navigation
  180    181    182    183    184  185  186    187    188    189    190  
TM 5-3895-374-24-1 Initial setting up Readjustment Adjustment parameters of the settings The adjustment parameters can be displayed and modified at any moment, whether the speed controller is running or not Modification of the setting parameters EXAMPLE The value of the parameters is stored in a permanent memory (EEPROM) In the event of a parameter value being changed, the new value is recorded in the memory, either the moment that another parameter is called up, or at the end of 10 seconds If neither of these conditions is fulfilled (the controller is switched off before 10 seconds has elapsed, for example), the parameter remains unchanged List of the parameters The acceleration time is increased automatically in the event of overtorque Preset value 5 s The deceleration time is increased automatically in the event of excessive braking (display of code Obr  ) Preset value 10 s (page 3-198)